Customization: | Available |
---|---|
After-sales Service: | Provide lifelong after-sales service |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Coulometric titration can be used to determine the water content of solid and gas samples reliably. During detection, insoluble solid reagents and easily contaminated electrodes and reagent materials can be equipped with corresponding solid, gas and liquid ejectors for indirect determination. It is an efficient and automatic analytical instrument. It is widely used in electric power, petroleum, chemical industry, pharmacy, railway, environmental protection, scientific research institutions and other industries.
Technical Indicators
Technical parameters | Detailed parameters |
Drop formula | electric quantity tit-ration (Coulomb analysis) |
Range | 0ug~ 200mg (10ug ~ 100ug) |
Threshold | 0.1ug |
Accuracy | 3-1000ug ±3ug, The above 1000ug is not more than ±0.2% (Error without sampling, ambient humidity ) |
Test sample type | solid, liquid, gas |
Display formula | 64K color high definition touch monitor |
Data storage | 1000 test records |
State indication | Dynamic curve, text display |
Stir mixing speed | sliding touch panel speed control |
Time period | ten years of normal operation of power down time |
Printer | micro thermal printer, paper width 56mm |
Power source | 220V 10V + AC, 50Hz + 2.5Hz |
Work rate | 50VA |
Ambient temperature | 5~35ºC |
Ambient humidity | ≤85% |
Shape size | 330*260*220mm |
Product picture
Device display
1. Electrode open circuit fault and short circuit fault auto-detection function
2. Built-in thermal printer, can do off-line printing
3. With Screen protection function to extend LCD life span
4. High precision and rapid measuring speed