Automatic Underground Cable Pipe Detector Location System

Product Details
Customization: Available
After-sales Service: Provide lifelong after-sales service
Warranty: 1 Year
Still deciding? Get samples of US$ 6240/Piece
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
40
Year of Establishment
2012-02-28
  • Automatic Underground Cable Pipe Detector Location System
  • Automatic Underground Cable Pipe Detector Location System
  • Automatic Underground Cable Pipe Detector Location System
  • Automatic Underground Cable Pipe Detector Location System
  • Automatic Underground Cable Pipe Detector Location System
  • Automatic Underground Cable Pipe Detector Location System
Find Similar Products

Basic Info.

Model NO.
ZXPD3000
Certification
CE, ISO
Condition
New
Customized
Customized
Alarm Form
LCD
Output frequency
640Hz, 1280Hz, 10kHz, 33kHz, 82kHz, 197kHz.
Output power
10W, 10 levels adjustable
Volume
transmitter 280*220*90mm, receiver 680*120*277mm
Charger
input AC100~240V, 50/60Hz, output DC8.4V, 2A
Mass
2.3kg for transmitter and 2.0kg for receiver.
Operating conditions
temperature: -10-40C, humidity 5-90%RH,
Altitude
<4500m
Transport Package
Carton/Wooden Case
Specification
300*270*200 mm
Trademark
GDZX
Origin
Hubei
Production Capacity
500 Pieces/Month

Product Description

Underground Pipeline Detector For Path Detection of Underground Cables

   
Automatic Underground Cable Pipe Detector Location System

       ZXPD3000 Underground pipeline detector is a high-performance underground metal pipeline detection system consisting of a signal transmitter and a receiver. It can be used for path detection, pipeline survey and depth measurement of metal pipelines and underground cables. It can be identified with a variety of optional accessories. As well as the search for pipe insulation damage and some types of cable faults.

Automatic Underground Cable Pipe Detector Location SystemAutomatic Underground Cable Pipe Detector Location System

Technical Indicators
 

Transmitter Output frequency: 640Hz, 1280Hz, 10kHz, 33kHz, 82kHz, 197kHz
Output power: 10W, 10 levels adjustable, automatic real-time impedance matching.
Direct connection output voltage: 150Vpp.
Receiver Active detection frequency: 640Hz, 1280Hz, 10kHz, 33kHz, 82kHz, 197kHz.
Power frequency passive detection frequency: 50Hz/60Hz and 250Hz/300Hz (user configurable).
Radio frequency passive detection frequency band: the center frequency is 10kHz, 33kHz, 82kHz respectively.
Volume Transmitter 280×220×90mm;
Receiver 680×120×277mm
Weight 2.3kg for transmitter and 2.0kg for receiver.
Charger Input AC100~240V, 50/60Hz;
Output DC8.4V, 2A.
Operating conditions Temperature: -10ºC-40ºC;
Humidity:5-90%RH;
Altitude <4500m

1. Transmitter

1) Output mode: direct output, radiation induction, caliper coupling (optional), fault-checking booster (optional).

2) Output frequency: 640Hz, 1280Hz, 10kHz, 33kHz, 82kHz, 197kHz.

3) Output power: 10W, 10 levels adjustable, automatic real-time impedance matching.

4) Direct connection output voltage: 150Vpp.

5) Overload and short circuit protection.

6) Man-machine interface: 320×240 dot matrix liquid crystal display.

7) Built-in battery: 4 18650 lithium ion batteries, nominal 7.4V, 6.8Ah.

2. Receiver

1) Input mode: built-in receiving coil, flexible caliper (optional), stethoscope (optional), fault checking A-frame (optional).

2) Receiving frequency:

    Active detection frequency: 640Hz, 1280Hz, 10kHz, 33kHz, 82kHz, 197kHz.

    Power frequency passive detection frequency: 50Hz/60Hz and 250Hz/300Hz (user configurable). Radio frequency passive            Detection frequency band: the center frequency is 10kHz, 33kHz, 82kHz respectively.

3) Pipeline detection mode: broad peak method, narrow peak method, sound valley method.

4) Cable identification mode: flexible caliper (optional) intelligent identification and current measurement, stethoscope (optional) identification.

5) Man-machine interface: 320×240 dot matrix liquid crystal display.

6) Built-in battery: 2 18650 lithium ion batteries, nominal 7.4V, 3.4Ah.

3. Other

1) Volume: transmitter 280×220×90mm, receiver 680×120×277mm.

2) Mass: 2.3kg for transmitter and 2.0kg for receiver.

3) Charger: input AC100~240V, 50/60Hz, output DC8.4V, 2A.

4) Operating conditions: temperature: -10ºC-40ºC, humidity 5-90%RH, altitude <4500m.
4. Configuration table
Automatic Underground Cable Pipe Detector Location System

      Automatic Underground Cable Pipe Detector Location System

       

      Device display
      Automatic Underground Cable Pipe Detector Location System
      Automatic Underground Cable Pipe Detector Location SystemAutomatic Underground Cable Pipe Detector Location System
      About GDZX
      Automatic Underground Cable Pipe Detector Location SystemAutomatic Underground Cable Pipe Detector Location SystemAutomatic Underground Cable Pipe Detector Location System

      Shipping and packaging
      Automatic Underground Cable Pipe Detector Location System

      Features

      1. Compass and direction display: visually display pipeline position and left-right direction.

      2. Tracking right and wrong prompts: current direction measurement, tracking right and wrong prompts, eliminating adjacent line interference (partial frequencies).

      3. Depth and current measurement, can display signal strength history curve.

      4. Fully digital high-precision sampling processing: stable and reliable, ultra-high sensitivity, extremely narrow receiving passband, strong anti-interference ability, and can fully suppress the power frequency and harmonic interference of adjacent running cables and pipelines.

      5. Running cable detection: high-performance launch calipers, coupling output signals to running cables.

      6. Cable/pipeline identification: The flexible caliper (optional accessory) is easy to use, and the identification result is clearly given; the stethoscope (optional accessory) can be used when the caliper is inconvenient to use.

      7. Ground fault finding: the booster (optional) can increase the output voltage to 1000V, and the A-frame (optional) can be used to locate the damaged point of the pipeline to the ground insulation without zero adjustment. The arrow indicates the direction of the fault point.

      8. Multiple detection frequencies: active detection and passive detection.

      9. Multiple signal output modes of the transmitter: direct connection output, clamp coupling, radiation induction.

      10. Transmitter digital amplifier power output, automatic impedance matching, automatic protection.

      11. Built-in removable large-capacity lithium-ion battery, automatic shutdown under voltage, and automatic shutdown without operation for a long time.

      12. The cabinet is beautiful and firm, lightweight and portable.