Strong Anti-interference Digital Single Clamp Grounding Resistance Tester

Product Details
Customization: Available
After-sales Service: Provided
Warranty: 1 Year
Manufacturer/Factory & Trading Company
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
40
Year of Establishment
2012-02-28
  • Strong Anti-interference Digital Single Clamp Grounding Resistance Tester
  • Strong Anti-interference Digital Single Clamp Grounding Resistance Tester
  • Strong Anti-interference Digital Single Clamp Grounding Resistance Tester
  • Strong Anti-interference Digital Single Clamp Grounding Resistance Tester
  • Strong Anti-interference Digital Single Clamp Grounding Resistance Tester
  • Strong Anti-interference Digital Single Clamp Grounding Resistance Tester
Find Similar Products

Basic Info.

Model NO.
ETCR Series
Resistance accuracy max
+/-1%+/-0.01Ohm
Power Supply
6VDC 4 PCS of AA Alkaline batterie
*Alarm Threshold Setting Range*
Resistance: 1-199Ohm * C type only
Working Temperature and Humidity
-20-55centigrade; 20%RH-90%RH
LCD Screen
4 Digits LCD display, Screen L*W: 47mm*28.5mm
Tester Weight
< 2KG
Measured current frequency
50/60Hz Automatic measurement
Auto Power-off
5 minutes after Boot up
Transport Package
Wooden Case or Carton
Specification
Universal Testing Machine
Trademark
GDZX
Origin
China
Production Capacity
1200sets/Year

Product Description

Strong Anti-interference Digital Single Clamp Grounding Resistance Tester

Introduction

Strong Anti-interference Digital Single Clamp Grounding Resistance Tester
   

     ETCR series Earth Clamp Meter is widely used in the grounding resistance measurement of electric power, telecommunications, meteorology, oilfield, construction and the industrial and electrical equipment.The measurement does not require disconnecting the grounding wire, need no auxiliary electrode. 

 

 

Strong Anti-interference Digital Single Clamp Grounding Resistance Tester
Strong Anti-interference Digital Single Clamp Grounding Resistance Tester

 

    Technical parameters 
    Model Jaws size Resistance range Current range Data upload  Alarm  Data save   
    ETCR2000A Long type 65×32mm 0.01Ω-200Ω × × × ×  
    ETCR2000 0.01Ω-1000Ω × × × ×  
    ETCR2000C 0.01Ω-1000Ω 0.00mA-20.0A ×  
    ETCR2000A+ 0.01Ω-200Ω × ×/√  
    ETCR2000+ 0.01Ω-1200Ω × ×/√  
    ETCR2000B+ 0.01Ω-1200Ω × ×/√  
    ETCR2000C+ 0.01Ω-1200Ω 0.00mA-20.0A ×/√  
    ETCR2000E+ 0.01Ω-1200Ω 0.00mA-40.0A  
    ETCR2100A Round type ∮32mm 0.01Ω-200Ω × × × ×  
    ETCR2100 0.01Ω-1000Ω × × × ×  
    ETCR2100C 0.01Ω-1000Ω 0.00mA-20.0A ×  
    ETCR2100A+ 0.01Ω-200Ω × ×/√  
    ETCR2100+ 0.01Ω-1200Ω × ×/√  
    ETCR2100C+ 0.01Ω-1200Ω 0.00mA-20.0A ×/√  
    ETCR2100E+ 0.01Ω-1200Ω 0.00mA-40.0A  
    Function Ground resistance test, contact resistance test
    Resistance accuracy max ±1%±0.01Ω
    Current accuracy max ±2.5%±1mA
    Power Supply 6VDC 4 PCS of AA Alkaline batteries
    *Alarm Threshold Setting Range* Resistance: 1-199Ω * C type only
    Alarm Sound and Light "Beep-beep-beep" alarm tone, Alarm Symbol Flashing, Press AL key to turn on, 
    turn off Alarm or set Alarm Threshold.
    Interference Signal Recognition "Beep-beep-beep" tone, NOISE symbol blinking
    Working Temperature and Humidity -20°c-55°c; 20%RH-90%RH
    LCD Screen 4 Digits LCD display, Screen L*W: 47mm*28.5mm
    Clamp Opening Extent 32mm
    Tester Weight < 2KG
    Protection Level Dual Insulation
    Structural Feature Clamp CT
    range Shifting Automatic shifting
    External magnetic field <40A/m
    External electrical field <1V/m
    Single measurement time <1 second
    Resistance measurement frequency >1KHz
    Measured current frequency 50/60Hz Automatic measurement
    Low Battery Indication Low battery symbol displays when battery is lower then 5.3V
    Memory Full Indication MEM symbol blinks when all 99 sets memory is full
    Over Range Indication Out of range indication "OLΩ", "L0.01" or "OL A"
    Auto Power-off 5 minutes after Boot up
    Power Consumption Max 50mA either in booting up or normally working, Continuously working for 30 hours
    RS232 Interface (Optional) The data stored in the meter are uploaded to the computer through RS232 interface and data wire, Then generate report files
    Accessories Meter: 1 piece, Test ring: 1 Piece, Meter Suitcase: 1 Piece, Manual 1 Copy
     Strong Anti-interference Digital Single Clamp Grounding Resistance Tester

    Test cases
    Strong Anti-interference Digital Single Clamp Grounding Resistance TesterStrong Anti-interference Digital Single Clamp Grounding Resistance Tester
    Strong Anti-interference Digital Single Clamp Grounding Resistance Tester
     
     

    Company introduction

    Strong Anti-interference Digital Single Clamp Grounding Resistance Tester

    Strong Anti-interference Digital Single Clamp Grounding Resistance Tester

     

    Strong Anti-interference Digital Single Clamp Grounding Resistance Tester


    Service and Warranty

    Strong Anti-interference Digital Single Clamp Grounding Resistance Tester

     


    PACKING AND SHIPPING

    (1)We will ship products within 8-20 working days after the receipt of confirmation of your payment.

    (2)All products will be well packed by robust carton or wooden box so as to ensure goods can arrive safely.
    (3)Multiple shipping methods including express, sea freight, railway and so on for your choice, competitive shipping method will be advised to you.
    (4)If you go with your own forwarder, we will provide all necessary documents for customs clearance.
    (5)After shipping, we will remain attentive till goods well received.
     
    If you need detailed specification, please feel free to contact us.
    Strong Anti-interference Digital Single Clamp Grounding Resistance Tester
     

    Features

    1. This instrument is suitable for grounding leads of various shapes (round steel, flat steel and angle steel).

    2. Non-contact measurement of grounding resistance is safe and fast.

    3. There is no need to use auxiliary grounding rod and interrupt the grounding of the equipment to be tested.

    4. Double protective insulation.

    5. Strong anti-interference and high measurement accuracy.

    6. Use No. 5 alkaline battery for user's convenience.

      Send your message to this supplier

      *From:
      *To:
      *Message:

      Enter between 20 to 4,000 characters.

      This is not what you are looking for? Post a Sourcing Request Now
      Contact Supplier
      Product Groups
      More