30Hz to 300Hz kV Cable Long KM distance AC Series Resonant Test System Hipot and Partial Discharge High Voltage Test Equipment

Product Details
Customization: Available
After-sales Service: Provide lifelong after-sales service
Warranty: 1 Year
Manufacturer/Factory & Trading Company
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
40
Year of Establishment
2012-02-28
  • 30Hz to 300Hz kV Cable Long KM distance AC Series Resonant Test System Hipot and Partial Discharge High Voltage Test Equipment
  • 30Hz to 300Hz kV Cable Long KM distance AC Series Resonant Test System Hipot and Partial Discharge High Voltage Test Equipment
  • 30Hz to 300Hz kV Cable Long KM distance AC Series Resonant Test System Hipot and Partial Discharge High Voltage Test Equipment
  • 30Hz to 300Hz kV Cable Long KM distance AC Series Resonant Test System Hipot and Partial Discharge High Voltage Test Equipment
  • 30Hz to 300Hz kV Cable Long KM distance AC Series Resonant Test System Hipot and Partial Discharge High Voltage Test Equipment
  • 30Hz to 300Hz kV Cable Long KM distance AC Series Resonant Test System Hipot and Partial Discharge High Voltage Test Equipment
Find Similar Products

Basic Info.

Model NO.
ZXBXZ
Output Frequency
30 ~ 300Hz
Application
Substation Primary Equipment Under 550kv or Below
Wave form
pure sine wave, THD <1.0%
Duty Cycle
Continuous working for 60mins once
Frequency adjustment sensitivity
0.1Hz, instability <0.05%
Power Supply
380/220V ± 15% / 50Hz ± 5%
Transport Package
Plywood Case
Specification
Can Be Customized
Trademark
GDZX
Origin
China
HS Code
9030339000
Production Capacity
5000PCS/Year

Product Description

0 - 1000kV AC Resonant Test System High Voltage Test Equipment for Substation
30Hz to 300Hz kV Cable Long KM distance AC Series Resonant Test System Hipot and Partial Discharge High Voltage Test Equipment
    ZXBXZ Series Resonant test system for Substation are designed for AC withstand voltage test of substation primary equipment under 550KV or below, mainly composed of variable-frequency power supply, exciting transformer, reactor and capacitive Voltage divider.

30Hz to 300Hz kV Cable Long KM distance AC Series Resonant Test System Hipot and Partial Discharge High Voltage Test Equipment
Technical parameters 

1.Rated output voltage: 0 - 1000kV, output frequency: 30 ~ 300Hz.Waveform: pure sine wave, THD <1.0%.

2.Duty Cycle: Continuous working time 60mins one time at full power output.

3.Quality factor: 30-90. Frequency adjustment sensitivity: 0.1Hz, instability <0.05%.

4.Power Supply: 380/220V±15%, 50Hz ± 5%.
30Hz to 300Hz kV Cable Long KM distance AC Series Resonant Test System Hipot and Partial Discharge High Voltage Test Equipment

30Hz to 300Hz kV Cable Long KM distance AC Series Resonant Test System Hipot and Partial Discharge High Voltage Test Equipment
 
30Hz to 300Hz kV Cable Long KM distance AC Series Resonant Test System Hipot and Partial Discharge High Voltage Test Equipment
30Hz to 300Hz kV Cable Long KM distance AC Series Resonant Test System Hipot and Partial Discharge High Voltage Test Equipment


30Hz to 300Hz kV Cable Long KM distance AC Series Resonant Test System Hipot and Partial Discharge High Voltage Test Equipment30Hz to 300Hz kV Cable Long KM distance AC Series Resonant Test System Hipot and Partial Discharge High Voltage Test Equipment
 
 

Company introduction

    Wuhan GDZX Power Equipment Co.,Ltd.is a manufacturer of power test equipment, integrating design, production and sales, providing complete solutions for high-voltage testing and electrical testing services for various power users.The main products include:AC series resonance test device, high voltage test equipment, transformer test equipment, secondary protection / switch test equipment, cable fault tester, arrester test equipment, power metering equipment, standard source series and so on. There are many kinds of products and complete models.

 

 

30Hz to 300Hz kV Cable Long KM distance AC Series Resonant Test System Hipot and Partial Discharge High Voltage Test Equipment

30Hz to 300Hz kV Cable Long KM distance AC Series Resonant Test System Hipot and Partial Discharge High Voltage Test Equipment


Service and Warranty

 

Service

* Provide professional consulting service; dedicated salesman and professional technical engineer to answer customer questions.
* Ensure customer get the detailed information about the product in hand.
* Reasonable price, we trust our customers should get the worth what they paid. Quotation stamped and confirmed by Manager.
* Welcome customers visit.

* The contract and the technical agreement to sign by both parties.
* Being trustworthy, follow the requirements and ensure successful implementation of signed contracts and technical agreements.
* Focus on communication, actively communicate with users, take notes of user's questions and schedule, provide the necessary technical support.
* Move quick and efficient, professional on delivery, installation, debugging, training and others.
 
Warranty
* We maintains 100% customer satisfaction, please give us feedback if you fell anything wrong with the product, we will make it right for you.
* Our products are guaranteed with one year warranty and life-long tech support.
* Provide solutions within 24 hours when there is problems feedback from customer.
30Hz to 300Hz kV Cable Long KM distance AC Series Resonant Test System Hipot and Partial Discharge High Voltage Test Equipment


PACKING AND SHIPPING

(1)We will ship products within 8-20 working days after the receipt of confirmation of your payment.

(2)All products will be well packed by robust carton or wooden box so as to ensure goods can arrive safely.
(3)Multiple shipping methods including express, sea freight, railway and so on for your choice, competitive shipping method will be advised to you.
(4)If you go with your own forwarder, we will provide all necessary documents for customs clearance.
(5)After shipping, we will remain attentive till goods well received.
 
If you need detailed specification, please feel free to contact us.
30Hz to 300Hz kV Cable Long KM distance AC Series Resonant Test System Hipot and Partial Discharge High Voltage Test Equipment


Features

    1.Easy to operate, two working modes: manual and automatic.

    2.Can set Test Voltage, frequency range, protective current and operating time.

    3.Smaller size, lighter weight compared with same voltage level same capacity reactor.

    4.Small temperature rise at rated load. Strong protection, good stability. Multiple functions, cost effective.

    5.Dry type epoxy cast, high mechanical strength, good insulation, nice and reliable.

    6.Adjustable capacity of frequency control source.

    7.With 220V or 380V single phase power, convenient for on-site power sourcing.

    8.Flexible configuration. Different type reactors for option to meet different test object requirements. 