Transformer Load & No-load Loss Tester With Short Circuit Voltage Test

Product Details
Customization: Available
After-sales Service: Provided
Warranty: 1 Year
Manufacturer/Factory & Trading Company
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
40
Year of Establishment
2012-02-28
  • Transformer Load & No-load Loss Tester With Short Circuit Voltage Test
  • Transformer Load & No-load Loss Tester With Short Circuit Voltage Test
  • Transformer Load & No-load Loss Tester With Short Circuit Voltage Test
  • Transformer Load & No-load Loss Tester With Short Circuit Voltage Test
  • Transformer Load & No-load Loss Tester With Short Circuit Voltage Test
  • Transformer Load & No-load Loss Tester With Short Circuit Voltage Test
Find Similar Products

Basic Info.

Model NO.
ZX-BZL
Power Input
AC220V+-10%;
Current measurement range
100mA ~ 60A, accuracy class 0.2;
Voltage Range
10V ~ 650V, accuracy class 0.2;
Frequency Range
40 ~ 65Hz, accuracy class 0.2;
Test accuracy
0.2 class
Currrent measurement range
0.5-60A
Voltage measurement range
10-600V
Temperature
-5C-40C
Relative humidity
less than 95%(25 centigrade)
Transport Package
Wooden Case or Carton
Specification
Universal Testing Machine
Trademark
GDZX
Origin
China
Production Capacity
1200sets/Year

Product Description

Transformer Load & No-load Loss Tester With Short Circuit Voltage Test

Introduction
 

Transformer Load & No-load Loss Tester With Short Circuit Voltage Test
     ZX-BZL Transformer Load & No-load Loss Tester can Simultaneous measure the effective value of AC voltage, average voltage, effective value, active power, power factor and frequency of single-phase or three-phase power transformer, the measurement accuracy is 0.1. Intelligent and professional design, suitable for power transformer no-load, load, induction test, is the ideal equipment for the traditional pointer instrument.  



Transformer Load & No-load Loss Tester With Short Circuit Voltage Test

    Transformer Load & No-load Loss Tester With Short Circuit Voltage Test

          Technical parameters 
          Technical parameter Detailed parameters
          Environment condition Temperature:-5°C~40°C
          Relative humidity:<95%(25°C)
          Altitude:<2500m
          External interference: no extra strong vibration and electromagnetic field.
          Power supply:220VAC±15%,50Hz~60Hz
          Measuring range Voltage:10~600V
          Current:0.5~60A
          Test accuracy Voltage,current and frequency:the measurement accuracy is 0.2
          Power:measurement error< ±0.5%(CosΦ>0.1),±1.0%(0.02<CosΦ<0.1)
          Insulation strength The insulation resistance of voltage and current input terminals to the casing shall be ≥ 100mOhm
          The power frequency 2KV(effective value)shall be borne between the input end of working power supply and the shell for 1 minute.
          Transformer Load &amp; No-load Loss Tester With Short Circuit Voltage Test
          Transformer Load &amp; No-load Loss Tester With Short Circuit Voltage Test

           


          Company introduction

              Wuhan GDZX Power Equipment Co.,Ltd.is a manufacturer of power test equipment, integrating design, production and sales, providing complete solutions for high-voltage testing and electrical testing services for various power users.The main products include:AC series resonance test device, high voltage test equipment, transformer test equipment, secondary protection / switch test equipment, cable fault tester, arrester test equipment, power metering equipment, standard source series and so on. There are many kinds of products and complete models.

          Transformer Load &amp; No-load Loss Tester With Short Circuit Voltage Test

           

           

          Transformer Load &amp; No-load Loss Tester With Short Circuit Voltage Test

           

           

          Service and Warranty

           

          Service

          * Provide professional consulting service; dedicated salesman and professional technical engineer to answer customer questions.
          * Ensure customer get the detailed information about the product in hand.
          * Reasonable price, we trust our customers should get the worth what they paid. Quotation stamped and confirmed by Manager.
          * Welcome customers visit.

          * The contract and the technical agreement to sign by both parties.
          * Being trustworthy, follow the requirements and ensure successful implementation of signed contracts and technical agreements.
          * Focus on communication, actively communicate with users, take notes of user's questions and schedule, provide the necessary technical support.
          * Move quick and efficient, professional on delivery, installation, debugging, training and others.
           
          Warranty
          * We maintains 100% customer satisfaction, please give us feedback if you fell anything wrong with the product, we will make it right for you.
          * Our products are guaranteed with one year warranty and life-long tech support.
          * Provide solutions within 24 hours when there is problems feedback from customer.
          Transformer Load &amp; No-load Loss Tester With Short Circuit Voltage Test

          PACKING AND SHIPPING

          (1)We will ship products within 8-20 working days after the receipt of confirmation of your payment.

          (2)All products will be well packed by robust carton or wooden box so as to ensure goods can arrive safely.
          (3)Multiple shipping methods including express, sea freight, railway and so on for your choice, competitive shipping method will be advised to you.
          (4)If you go with your own forwarder, we will provide all necessary documents for customs clearance.
          (5)After shipping, we will remain attentive till goods well received.
           
          If you need detailed specification, please feel free to contact us.
          Transformer Load &amp; No-load Loss Tester With Short Circuit Voltage Test
           
           
          Test cases
          Transformer Load &amp; No-load Loss Tester With Short Circuit Voltage Test
           
           
          Transformer Load &amp; No-load Loss Tester With Short Circuit Voltage Test
           
          Transformer Load &amp; No-load Loss Tester With Short Circuit Voltage Test
           
           

          Features

          1.Measure the transformer load current, load loss, short-circuit voltage, short circuit (load) losses.

          2.Harmonic test can be analyzed to 31 harmonics.

          3.Support Three Methods, two table method, two experimental methods.

          4.Do three-phase transformer no-load, load test, the instrument can automatically determine the wiring is correct, and shows three-phase voltage and current vector map.

          5.Single machine can do the following 1000KVA distribution transformer full load current experiment; in one third of the rated current, complete 2500KVA distribution transformer load the following test (in one third of the rated current, the instrument can be converted to load loss under rated current parameters, the machine is mainly used in the test bed with integrated supporting the use of transformers, the load characteristics to achieve high-precision transformer no-load test).

          6.All the related test results are automatically corrected. Instrument can automatically such as: the waveform correction, temperature correction, non-rated voltage correction, calibration, and other non-rated current correction, so that more accurate test results.

          7. 7.320x240 large screen, high brightness LCD display, full Chinese menu and operations to achieve prompt and friendly man-machine dialogue, touch buttons make the operation more convenient, wide LCD with brightness adjustment, can be adapted to the various summer and winter season.

          8.The instrument 40 can be preset by the user group is the test product parameters, and these parameters can be removed according to need and increase in use is very convenient.

          9.Comes with real-time clock, automatically recording test date, time, the preservation of favorable results, management.

          10.Panel-type thermal printer, the scene quickly print test results.

          11.Data (test sample set, the measurement results, the test of time, etc.) with power-down storage and browsing features, you can store 500 set of experimental results with computer on-line data transfer.

          12.Allows an external voltage transformer and current transformer for extended range of measurement, any measurable parameter is the test product.

          Send your message to this supplier

          *From:
          *To:
          *Message:

          Enter between 20 to 4,000 characters.

          This is not what you are looking for? Post a Sourcing Request Now
          Contact Supplier
          Product Groups
          More