Super Precision DC/AC Three Phase Standard Source Test Bench

Product Details
Customization: Available
After-sales Service: Provide lifelong after-sales service
Warranty: 1 Year
Still deciding? Get samples of US$ 42099/Piece
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
40
Year of Establishment
2012-02-28
Find Similar Products

Basic Info.

Model NO.
ZX3030H
Voltage range
10,20,50,100,200,400,600V
Current range
0.1,0.25,0.5,1,2.5,5,10,25,50,100
Regulation range
0~120%
Regulation fineness
0.005%
Transport Package
Carton/Wooden Case
Specification
With the change of technical scheme
Trademark
GDZX
Origin
Hubei
Production Capacity
500 Pieces/Month

Product Description

ZX3030H DC/AC Three Phase Standard Source

  
Super Precision DC/AC Three Phase Standard Source Test Bench

It is composed of program control three phase standard source, DC standard source, Three phase sampling type multifunctional standard meter, and computer with standard table and management software installed.

Features
 

1. can semi-automatically or manually test the basic error of a variety of power frequency meters (voltmeter,ammeter, power meter, frequency meter, power factor meter, phase meter), and test the change value cause by influence of voltage, current, waveform and power factor

2. can automatically measure the basic errors of electric transducers (voltage transducer, current transducer, power transducer, frequency transducer, power factor transducer), and the change value caused by influence of votalge, current, waveform and power factors etc

3. can generate distortion wave with 2~31 order harmonic, harmonic number, order, amplitude and phase to fundamental wave all can be program controlled

4. Power amplifier's working frequency 40Hz~1KHz, good linearity. Current power amplifier is  constant-current source, and voltage power amplifier is constant-voltage source

5. Testing by PC automatic control or manual control, capaple of data analyzing and managing

6. can auto calibrate energy meters
 

Technical Indicators
 

1. AC output voltage current

Voltage range: 10,20,50,100,200,400,600V

Current range: 0.1,0.25,0.5,1,2.5,5,10,25,50,100

Regulation range: 0~120%( but 800V,100A: 105% )

Regulation fineness: 0.005%

Output voltage current power stability:  ≤0.01%/60s

maximum output capacity of voltage per phase: 50VA

maximum output capacity of current per phase: 100VA

sine wave output distortion: ≤0.3%

2. Output phase

Phase drift of current to the same voltage: 0.000~359.990

Regulation fineness: 0.010

3. output frequency

Regulation range: 45~65Hz 

Setting value accuracy : 5×10-5
4. Distortion wave output

Harmonic order: 2-31

Harmonic numbers contented at the same time: 0~30

Harmonic amplitude: total harmonic peak-peak value, should not be more than 50% of fundamental wave rated value (voltage current range, expressed in peak-peak value), besides, distortion wave peak-peak value including fundamental wave should not be more than 125% of fundamental wave rated value.

Phase drift of each order harmonic to fundamental wave( fundamental wave positive zero crossing as reference): 0~360°

5. Three phase angle symmetry

Three phase four line: between the phase voltage: 1200±0.20

Three phase three line: UAB is UCB lagging behind 600±0.20

6. DC output voltage ( auxiliary range not included)

Range: mV:100,300
   V:1,3,10,30,100,300,600,1000

7. DC output current ( auxiliary range not included)

uA:10,30,100,300
mA:1,3,10,30,100,300
A:1,3,10,30 

8. DC output capacity: maximum 30W

9. DC output regulation range and fineness

Range: 0~120% ( but voltage 1000V, current 30A: 105%)

Fineness: 0.002%

10. DC output accuracy: 0.05%

11. stability of DC full range output: ≤±0.01% RG/1min

12. error caused by ripple and noise voltage: ≤±0.01% RG

13. error caused by loading change of no-load to full-load: ≤±0.01% RG

14. device accuracy class: 0.05

1) allowed measuring error of voltage/current/active power: (5V≤U≤1000V,0.1A≤I≤100A) 0.05%

2) allowed measuring error of active power energy: (25V≤U≤800V, 0.1A≤I≤100A) 0.05%

3) allowed measuring error of reactive power/energy: 0.1%

4) phase measuring error: ±0.050

5) power factor measuring error: ±0.0002

15. Power supply: Single phase 220V±10%, 50HZ±5%

16. working environment: temperature 200ºC±100ºC, relative humidity ≤85%RH

17. dimension and weight: 1800×800×750mm3, 135kg


Product pictures
Super Precision DC/AC Three Phase Standard Source Test Bench

Device display
Super Precision DC/AC Three Phase Standard Source Test Bench
Super Precision DC/AC Three Phase Standard Source Test Bench
About GDZX
     Wuhan GDZX Power Equipment Co.,Ltd.is a manufacturer of power test equipment, integrating design, production and sales, providing complete solutions for high-voltage testing and electrical testing services for various power users.The main products include:AC series resonance test device, high voltage test equipment, transformer test equipment, secondary protection / switch test equipment, cable fault tester, arrester test equipment, power metering equipment, standard source series and so on. There are many kinds of products and complete models.
Super Precision DC/AC Three Phase Standard Source Test Bench
Super Precision DC/AC Three Phase Standard Source Test BenchSuper Precision DC/AC Three Phase Standard Source Test BenchSuper Precision DC/AC Three Phase Standard Source Test Bench
Shipping and packaging
Super Precision DC/AC Three Phase Standard Source Test Bench

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More