2022 New Version 10KV Low Voltage Short-circuit Impedance Measurement of Main Transformer

Product Details
Customization: Available
After-sales Service: Provided
Warranty: 1 Year
Manufacturer/Factory & Trading Company
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
40
Year of Establishment
2012-02-28
Find Similar Products

Basic Info.

Model NO.
ZX-BZK
Measurement accuracy
Voltage, current 0.2%
Voltage measurement range
AC 3V-300V
Internal power supply output range
voltage 0-250V, current 0-10A
Current measuring range
AC 0.2A-20A
Humidity
0-80%
Power supply
AC220V+-10%,50Hz+-1Hz
Dimension
360*220*150mm
Weight
about 5kg
Transport Package
Wooden Case or Carton
Specification
Universal Testing Machine
Trademark
GDZX
Origin
China
Production Capacity
1200sets/Year

Product Description

10KV Low Voltage Short-circuit Impedance Measurement of Main Transformer

Introduction

2022 New Version 10KV Low Voltage Short-circuit Impedance Measurement of Main Transformer
      ZX-BZK Transformer Short-circuit Impedance Tester is to the most direct way to check the deformation of the winding after transformer suffered from short-circuit current or mechanical collision during transportation and installation, the test is important to help determine whether the transformer can be put into operation, and whether disintegration is necessary for inspection. 



 

                          2022 New Version 10KV Low Voltage Short-circuit Impedance Measurement of Main Transformer
                          Technical parameters 
                           
                          1.Measurement accuracy Voltage, current 0.2%
                          2.Power COSφ>0.1 0.5%; COSφ≤0.1 1.0%
                           
                          3.Impedance
                           
                          COSφ>0.1 0.5%; COSφ≤0.1 1.0%
                          4.Voltage measurement range
                           
                           AC 3V-300V
                          5.Internal power supply output range
                           
                          voltage 0-250V, current 0-10A
                          6.Current measuring range
                           
                          : AC 0.2A-20A
                          7.Working temperature
                           
                           -10ºC-50ºC
                          8.Humidity
                           
                          0-80%
                          9.Power supply
                           
                          AC220V±10%,50Hz±1Hz
                          10.Dimension
                           
                          360*220*150mm
                          11.Weight
                           
                          about 5kg
                           2022 New Version 10KV Low Voltage Short-circuit Impedance Measurement of Main Transformer2022 New Version 10KV Low Voltage Short-circuit Impedance Measurement of Main Transformer
                          Test cases
                          2022 New Version 10KV Low Voltage Short-circuit Impedance Measurement of Main Transformer2022 New Version 10KV Low Voltage Short-circuit Impedance Measurement of Main Transformer2022 New Version 10KV Low Voltage Short-circuit Impedance Measurement of Main Transformer
                           

                          Company introduction

                          2022 New Version 10KV Low Voltage Short-circuit Impedance Measurement of Main Transformer

                          2022 New Version 10KV Low Voltage Short-circuit Impedance Measurement of Main Transformer2022 New Version 10KV Low Voltage Short-circuit Impedance Measurement of Main Transformer2022 New Version 10KV Low Voltage Short-circuit Impedance Measurement of Main Transformer

                          Service and Warranty

                           

                          Service

                          * Provide professional consulting service; dedicated salesman and professional technical engineer to answer customer questions.
                          * Ensure customer get the detailed information about the product in hand.
                          * Reasonable price, we trust our customers should get the worth what they paid. Quotation stamped and confirmed by Manager.
                          * Welcome customers visit.

                          * The contract and the technical agreement to sign by both parties.
                          * Being trustworthy, follow the requirements and ensure successful implementation of signed contracts and technical agreements.
                          * Focus on communication, actively communicate with users, take notes of user's questions and schedule, provide the necessary technical support.
                          * Move quick and efficient, professional on delivery, installation, debugging, training and others.
                           
                          Warranty
                          * We maintains 100% customer satisfaction, please give us feedback if you fell anything wrong with the product, we will make it right for you.
                          * Our products are guaranteed with one year warranty and life-long tech support.
                          * Provide solutions within 24 hours when there is problems feedback from customer.
                          2022 New Version 10KV Low Voltage Short-circuit Impedance Measurement of Main Transformer

                           


                          Features

                            1. With switching power supply, just one time wiring connection can finish measurement for all the windings, no matter it is single phase transformer or three phase transformer

                            2. Single phase measurement mode. To three phase transformers, each phase short circuit impedance, reactance, inductance can be obtained automatically after three times boosting.

                            3. Adopts phase locking technology, synchronize sampling AC signal which ensures accuracy

                            4. current, voltage and power, frequency can be measured at the same time

                            5. Support external connection with CT/PT to extend measuring range

                            6. With memory to store data, with printer

                            7. LCD display with operation menu, data can be read clearly even under direct sunlight

                            Send your message to this supplier

                            *From:
                            *To:
                            *Message:

                            Enter between 20 to 4,000 characters.

                            This is not what you are looking for? Post a Sourcing Request Now
                            Contact Supplier
                            Product Groups
                            More