• Factory Direct Sale Three Phase Transformer No-load And Load Characteristic Tester
  • Factory Direct Sale Three Phase Transformer No-load And Load Characteristic Tester
  • Factory Direct Sale Three Phase Transformer No-load And Load Characteristic Tester
  • Factory Direct Sale Three Phase Transformer No-load And Load Characteristic Tester
  • Factory Direct Sale Three Phase Transformer No-load And Load Characteristic Tester

Factory Direct Sale Three Phase Transformer No-load And Load Characteristic Tester

After-sales Service: Provide lifelong after-sales service
Warranty: 1 Year
Current measurement range: 100mA ~ 60A
Voltage Range: 10V ~ 650V
Frequency Range: 40 ~ 65Hz
Accuracy: 0.2 Class
Samples:
US$ 2100/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ZX-BZL
Transport Package
Carton/Wooden Case
Specification
With the change of technical scheme
Trademark
GDZX
Origin
Hubei
Production Capacity
500 Pieces/Month

Product Description

ZX-BZL Transformer Load & No-load Loss Tester

   
Factory Direct Sale Three Phase Transformer No-load And Load Characteristic Tester

ZX-BZL Transformer Load & No-load Loss Tester can Simultaneous measure the effective value of AC voltage, average voltage, effective value, active power, power factor and frequency of single-phase or three-phase power transformer, the measurement accuracy is 0.1. Intelligent and professional design, suitable for power transformer no-load, load, induction test, is the ideal equipment for the traditional pointer instrument.

Features
 

1.Measure the transformer load current, load loss, short-circuit voltage, short circuit (load) losses.

2.Harmonic test can be analyzed to 31 harmonics.

3.Support Three Methods, two table method, two experimental methods.

4.Do three-phase transformer no-load, load test, the instrument can automatically determine the wiring is correct, and shows three-phase voltage and current vector map.

5.Single machine can do the following 1000KVA distribution transformer full load current experiment; in one third of the rated current, complete 2500KVA distribution transformer load the following test (in one third of the rated current, the instrument can be converted to load loss under rated current parameters, the machine is mainly used in the test bed with integrated supporting the use of transformers, the load characteristics to achieve high-precision transformer no-load test).

6.All the related test results are automatically corrected. Instrument can automatically such as: the waveform correction, temperature correction, non-rated voltage correction, calibration, and other non-rated current correction, so that more accurate test results.

7. 7.320x240 large screen, high brightness LCD display, full Chinese menu and operations to achieve prompt and friendly man-machine dialogue, touch buttons make the operation more convenient, wide LCD with brightness adjustment, can be adapted to the various summer and winter season.

8.The instrument 40 can be preset by the user group is the test product parameters, and these parameters can be removed according to need and increase in use is very convenient.

9.Comes with real-time clock, automatically recording test date, time, the preservation of favorable results, management.

10.Panel-type thermal printer, the scene quickly print test results.

11.Data (test sample set, the measurement results, the test of time, etc.) with power-down storage and browsing features, you can store 500 set of experimental results with computer on-line data transfer.

12.Allows an external voltage transformer and current transformer for extended range of measurement, any measurable parameter is the test product.
 

Technical Indicators

 

Main technical parameters

1.Current measurement range: 100mA ~ 60A, accuracy class 0.2;

2.Voltage Range: 10V ~ 650V, accuracy class 0.2;

External transformer can broaden the scope of measurement instruments;

1.Frequency Range: 40 ~ 65Hz, accuracy class 0.2;

2.Power Input: AC220V ± 10%;

      Product pictures
      Factory Direct Sale Three Phase Transformer No-load And Load Characteristic TesterFactory Direct Sale Three Phase Transformer No-load And Load Characteristic TesterFactory Direct Sale Three Phase Transformer No-load And Load Characteristic TesterFactory Direct Sale Three Phase Transformer No-load And Load Characteristic Tester
      Device display
      Factory Direct Sale Three Phase Transformer No-load And Load Characteristic Tester
      Factory Direct Sale Three Phase Transformer No-load And Load Characteristic Tester
      About GDZX
           Wuhan GDZX Power Equipment Co.,Ltd.is a manufacturer of power test equipment, integrating design, production and sales, providing complete solutions for high-voltage testing and electrical testing services for various power users.The main products include:AC series resonance test device, high voltage test equipment, transformer test equipment, secondary protection / switch test equipment, cable fault tester, arrester test equipment, power metering equipment, standard source series and so on. There are many kinds of products and complete models.
      Factory Direct Sale Three Phase Transformer No-load And Load Characteristic Tester
      Factory Direct Sale Three Phase Transformer No-load And Load Characteristic TesterFactory Direct Sale Three Phase Transformer No-load And Load Characteristic TesterFactory Direct Sale Three Phase Transformer No-load And Load Characteristic Tester
      Shipping and packaging
      Factory Direct Sale Three Phase Transformer No-load And Load Characteristic Tester

      Send your message to this supplier

      *From:
      *To:
      *Message:

      Enter between 20 to 4,000 characters.

      This is not what you are looking for? Post a Sourcing Request Now