CT Tester Current Transformer Parameters Tester with High Resolution LCD Screen

Product Details
Customization: Available
After-sales Service: Provide lifelong after-sales service
Warranty: 1 Year
Still deciding? Get samples of US$ 8000/Set
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
40
Year of Establishment
2012-02-28
Find Similar Products

Basic Info.

Model NO.
ZXCT-H
Instrument accuracy level
0.05 or 0.02 level
Test range
5A / 5A ~ 25000A / 5A or 5A / 1A ~ 6300A / 1A
Instrument power consumption
20VA
Maximum external dimension
460 * 375 * 183mm
Weight
10.0kg
Transport Package
Carton/Wooden Case
Specification
With the change of technical scheme
Trademark
GDZX
Origin
Hubei
Production Capacity
500 Pieces/Month

Product Description

ZXCT-H Current Transformer Field Calibrator

   
CT Tester Current Transformer Parameters Tester with High Resolution LCD Screen
 

 

 

ZXCT-H current transformer field calibrator was developed based on high-end testing technology, large-scale electronic circuit design and in compliance with relevant national regulations. It solves the problems of on-site verification of current transformer and voltage transformer with high working intensity and tedious operation. At the same time, the product has reliable performance and powerful functions.

 
Features
 

1. The instrument also has a recursive method to measure the current transformer error, which is convenient for the on-site verification of the measurement device.

2. On-site verification of current transformers does not require standard current transformers, current risers, load boxes, voltage control boxes and high-current conductors. It uses extremely simple test wiring and operations to achieve the verification of current transformers, greatly reducing the work The intensity and working efficiency are improved, which is convenient for the on-site verification of transformers.

3. The instrument has a standard voltage transformer equivalent to the same transformation ratio of the measured current transformer. Its accuracy can reach 0.05 level, and the transformation ratio and no-load error of the measured current transformer can be accurately measured. Then combine the test results of impedance and admittance to calculate the error of the transformer.

4. Adopt different frequency power supply test close to power frequency to prevent on-site power frequency electromagnetic radiation and series interference.

5. Wide measuring range, can reach 5A / 5A ~ 25000A / 5A or 5A / 1A ~ 6300A / 1A.

6. With the function of current transformer transformation ratio and secondary winding internal resistance test.

7. Adopt 800 × 600 high-resolution large-screen color liquid crystal display, with humanized interface and operation design, and use the touch screen to assist the operation, making the operation more convenient and fast.

8. Using precise software algorithms, the accuracy of measurement data is further improved.

9. It has the intelligence to judge the external wiring status, and prompts the wiring error, transformation ratio, polarity error, etc.

10. Automatically round the test data and judge whether it is out of tolerance. The out-of-tolerance data is displayed in orange and the out-of-tolerance is displayed at the lower right corner of the window.

11. Directly issue on-site verification conclusions, qualified or out of tolerance.

12. Large-scale memory can store up to 1000 field test data.

13. Use RS232 or USB interface to connect computer to print data certificate.

14. The engineering plastic mold chassis is used to prevent shock and pressure to ensure the safety of on-site operators and equipment.
 

Technical Indicators
1. Current transformer error measurement section

1) Overall accuracy: 1/3 of the error limit of the measured current transformer

2) Test range: 5A / 5A ~ 25000A / 5A or 5A / 1A ~ 6300A / 1A

Transformer rated primary current range with secondary current of 5A

5

7.5

10

15

20

25

30

40

50

60

75

80

100

120

150

160

200

250

300

315

400

500

600

630

750

800

1000

1200

1250

1500

1600

2000

2500

3000

3150

3200

4000

5000

6000

6300

Transformer rated primary current range with secondary current 1A

5

7.5

10

15

20

25

30

40

50

60

75

80

100

120

150

160

200

250

300

315

400

500

600

630

750

800

1000

1200

1250

1500

1600

2000

2500

3000

3150

3200

4000

5000

6000

6300

Note: The current transformer with a secondary current of 1A can be converted to 31500A / 1A by the method of equal-ampere turns measurement. Other test methods for the current transformer ratios that do not appear in the table are as follows:

Use the equal ampere-turn method to test the current transformer, for example: you need to test the 1000A / 5A transformer, please pass the test wire of the instrument through the two turns of the current transformer, and then test A current input is only 500A. This test method does not affect the validity of the transformer test data.

 Similarly, other transformation ratios use the following processing methods:

Rated once (A)

Number of turns

Instrument primary current (A)

80

2

40

120

2

60

8000

2

4000

12000

2

6000

3) Working range of the tested current transformer: 1% 200%

4) Secondary load: 2.5VA 300VA, COSφ = 0.1 1.0

5) Accuracy range of tested current transformer: 1.0, 0.5, 0.5S, 0.2 and 0.2S

6) Resistance / admittance measurement error: ≤5.0%

7) Measuring range: R: 0.00Ω 20.0Ω

              Y: 0.000mS 100.0mS

2. Part of the voltage transformer calibrator

1) Basic error:

a. In-phase component:

2. Part of the voltage transformer calibrator

1) Basic error:

a. In-phase component: X = (X × 2% + Y × 2% 2 words)

     Y = (X × 2% + Y × 2% 5 words)

     "X", "Y"-display value of the instrument

     "5 words"-quantization error of the instrument

b. Percentage Table: Level 1

c. Measuring range: f: 0.0000% 200.0%

             Δ: 0.000 ′ 999.9 ′

3. Instrument power consumption: 20VA

4. Instrument accuracy level: 0.05S level

5. Maximum external dimension: 460 × 375 × 183mm

6. Weight: 10.0kg


Product picture
CT Tester Current Transformer Parameters Tester with High Resolution LCD Screen
Device display

 
CT Tester Current Transformer Parameters Tester with High Resolution LCD Screen
 
CT Tester Current Transformer Parameters Tester with High Resolution LCD Screen

About GDZX
     Wuhan GDZX Power Equipment Co.,Ltd.is a manufacturer of power test equipment, integrating design, production and sales, providing complete solutions for high-voltage testing and electrical testing services for various power users.The main products include:AC series resonance test device, high voltage test equipment, transformer test equipment, secondary protection / switch test equipment, cable fault tester, arrester test equipment, power metering equipment, standard source series and so on. There are many kinds of products and complete models.
CT Tester Current Transformer Parameters Tester with High Resolution LCD Screen
CT Tester Current Transformer Parameters Tester with High Resolution LCD Screen
CT Tester Current Transformer Parameters Tester with High Resolution LCD ScreenCT Tester Current Transformer Parameters Tester with High Resolution LCD Screen
Shipping and packaging
 
CT Tester Current Transformer Parameters Tester with High Resolution LCD Screen
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More