Digital AC20mA 40V Double Clamp Grounding Resistance Tester For On Site

Product Details
Customization: Available
After-sales Service: Provided
Warranty: 1 Year
Manufacturer/Factory & Trading Company
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
40
Year of Establishment
2012-02-28
  • Digital AC20mA 40V Double Clamp Grounding Resistance Tester For On Site
  • Digital AC20mA 40V Double Clamp Grounding Resistance Tester For On Site
  • Digital AC20mA 40V Double Clamp Grounding Resistance Tester For On Site
  • Digital AC20mA 40V Double Clamp Grounding Resistance Tester For On Site
  • Digital AC20mA 40V Double Clamp Grounding Resistance Tester For On Site
  • Digital AC20mA 40V Double Clamp Grounding Resistance Tester For On Site
Find Similar Products

Basic Info.

Model NO.
ZXET3007
Electromagnetic characteristics
IEC61326(EMC)
Power supply
DC 7.4V 1.8Ah rechargeable lithium battery
Ground voltage
AC 0.0-100.0V
Test voltage waveform
Sine wave
Short circuit test current
AC 20mA Max
Open circuit test voltage
AC 40V Max
Instrument size
320mm*275mm*145mm
Line voltage
Measurement below AC 600V
Automatic shut-down
Automatic shutdown after 15 minutes
Withstand
AC 3700V / Rms(between circuit and case)
Transport Package
Wooden Case or Carton
Specification
Universal Testing Machine
Trademark
GDZX
Origin
China
Production Capacity
1200sets/Year

Product Description

Digital AC20mA 40V Double Clamp Grounding Resistance Tester For On Site

Introduction    
   The ZXET3007 Grounding resistance tester is designed and manufactured for field measurement of grounding resistance, soil resistivity, grounding voltage, and AC voltage in combination with the new lightning protection grounding resistance detection standard. The test current reaches 20mA, using digital and micro-processing technology. Precise 4-wire method, 3-wire method and simple 2-wire method for measuring ground resistance, introducing FFT (Fast Fourier Transform) technology and AFC (Automatic Frequency Control) technology to automatically identify interference and select the measurement frequency to minimize the impact of interference, provide more accurate ground resistance value.
Digital AC20mA 40V Double Clamp Grounding Resistance Tester For On Site


Digital AC20mA 40V Double Clamp Grounding Resistance Tester For On Site

 

      Technical Indicators
      Functions Ground resistance, soil resistivity test; ground voltage, AC voltage test
      Power supply DC 7.4V 1.8Ah rechargeable lithium battery, the battery is about 8.4V
      Backlight Controllable white screen backlight, suitable for use in dark places
      Measurement Precision 4-wire, 3-wire method measurement, simple 2-wire measurement of grounding resistance
      Measurement method Grounding resistance: rated current changing pole method, measuring current 20mA Max
      Soil resistivity: quadrupole method (Wenner method)
      Voltage to ground: average rectification (between P (S) -ES interface)
      Range Two, three, four wire method to measure grounding resistance (R): 0.000Ω ~ 300,000Ω
      Soil resistivity (Ρ): 0.00Ωm~9000kΩm
      Ground voltage: AC 0.0~100.0V
      Precision

      Two, three, four wire method to measure grounding resistance (R):

      ± 2% Rdg ± 5dgt (0.000Ω~29.999Ω)

      ± 2% Rdg ± 3dgt (30.00Ω~2999.9Ω)

      ± 4% Rdg ± 3dgt (3000Ω~300000Ω)

      Soil resistivity (Ρ): according to the measurement accuracy of R (Ρ=2πaR A: 1 M~100m; Π=3.14)
      Ground voltage: ± 2% Rdg ± 3dgt

      Note: 1. The additional error when RC Max or RP Max is ≤ ± 5% Rdg ± 5dgt. (RC Max: 4kΩ + 100R<50kΩ, RP Max: 4kΩ + 100R<50kΩ)

      2. Additional error at 5V interference voltage ≤ ± 5% Rdg ± 5dgt.

      Test voltage waveform Sine wave
      Test frequency 128Hz/111Hz/105Hz/94Hz (automatic frequency selection)
      Short circuit test current AC 20mA Max
      Open circuit test voltage AC 40V Max
      Electrode spacing 1m~100m

       

       

      Gear shift

      Grounding resistance: 0.000Ω~300,000Ω automatic gear shift
      Soil resistivity: 0.00Ωm ~ 9000kΩm automatic gear shift
      LCD 6-digit LCD display, white screen backlight
      LCD size 128mm × 75mm
      LCD display field 124mm × 67mm
      Measurement instructions LED flashing indication during measurement, LCD countdown, progress bar graph indication
      Charging instructions The indicator light on the charger lights red when charging, and lights green when fully charged
      Size Instrument size: length, width and height 320mm*275mm*145mm
      Outer packing size: 400mm*245mm*335mm
      Standard test line 4 bars: red 15m, black 15m, yellow 10m, green 10m each
      Simple test line 2 bars: red 1.6m, one black 1.6m each
      Auxiliary ground rod 4 pieces: Φ10mm*150mm
      Measure time Ground voltage: about 2 times/second; ground resistance: about 7 seconds/time; soil resistivity: about 7 seconds/time
      Measurement times More than 5000 times (short circuit test, test once, stop for 30 seconds and then test)
      Line voltage Measurement below AC 600V
      Communication Interface With RS232 interface, the stored data can be uploaded to the computer, saved and printed
      Communication line RS232 communication line, 1.5m 1 piece
      Data retention "HOLD" symbol indicates when holding data
      Data storage 2000 groups, "MEM" storage indication, display "FULL" indicates that the storage is full
      Data access "READ" symbol indicates when checking data
      Overflow display "OL" symbol indication when over-range overflow
      Interference test Automatically identify the interference signal, the interference voltage is higher than 5V "NOISE" symbol indication
      Auxiliary ground test With auxiliary earth resistance test function, 0.00kΩ~30.00kΩ (100R + RC <50kΩ, 100R + RP <50kΩ)
      Alarm function When the measured value exceeds the alarm setting value, "beep--beep--beep--" alarm prompt
      Battery voltage When the battery voltage is insufficient, the battery voltage low symbol is displayed to remind the battery to charge.
      Automatic shut-down Automatic shutdown after 15 minutes
      Working current Standby: 25mA Max (backlight off);
      Backlight: 25mA Max (separate backlight power consumption);
      When measuring: 150mA Max (backlight off)
      Quality Instrument: 2.66kg (including battery)
      Total mass: 6.88kg (including packaging)
      Tool box Special toolbox design, can bear 200kg
      Working temperature and humidity -10 ºC-40 ºC; below 80% Rh
      Storage temperature and humidity -20 ºC-60 ºC; below 70% Rh
      Overload protection Measurement of grounding resistance: AC 280V/3 seconds between C (H) -E, P (S) -ES ports
      Insulation resistance 20MΩ or more (500V between circuit and case)
      Withstand AC 3700V / Rms(between circuit and case)
      Electromagnetic characteristics IEC61326(EMC)
      Suitable for safety regulations IEC61010-1 (CAT III 300V, CAT IV 150V, pollution degree 2);
      IEC61010-031; IEC61557-1 (ground resistance); IEC61557-5 (soil resistivity); JJG 366-2004 (ground resistance meter)

      Product pictures

      Digital AC20mA 40V Double Clamp Grounding Resistance Tester For On Site
      Digital AC20mA 40V Double Clamp Grounding Resistance Tester For On SiteDigital AC20mA 40V Double Clamp Grounding Resistance Tester For On SiteDigital AC20mA 40V Double Clamp Grounding Resistance Tester For On Site

      Features

      1. This instrument is composed of host computer, data software, test line, auxiliary ground rod, communication line, etc.

      2. The special toolbox design of the host, using polypropylene plastic as the raw material, adding a new type of composite filler for one-time injection molding, has low density, strength, rigidity, hardness, wear resistance, heat resistance, and insulation performance, and its box can withstand a pressure of about 200kg, to ensure high accuracy, high stability and high reliability of various environmental tests.

      3. The large LCD display of the host, with backlight, bar graph indication, at a glance.

      4. Can store 2000 sets of data at the same time.

      5. The data software can realize the functions of historical data reading, consulting, saving, reporting, printing and so on.


      Company introduction

          Wuhan GDZX Power Equipment Co.,Ltd.is a manufacturer of power test equipment, integrating design, production and sales, providing complete solutions for high-voltage testing and electrical testing services for various power users.The main products include:AC series resonance test device, high voltage test equipment, transformer test equipment, secondary protection / switch test equipment, cable fault tester, arrester test equipment, power metering equipment, standard source series and so on. There are many kinds of products and complete models.
      Digital AC20mA 40V Double Clamp Grounding Resistance Tester For On Site


      Digital AC20mA 40V Double Clamp Grounding Resistance Tester For On Site
      Service and Warranty

       

      Service

      * Provide professional consulting service; dedicated salesman and professional technical engineer to answer customer questions.
      * Ensure customer get the detailed information about the product in hand.
      * Reasonable price, we trust our customers should get the worth what they paid. Quotation stamped and confirmed by Manager.
      * Welcome customers visit.

      * The contract and the technical agreement to sign by both parties.
      * Being trustworthy, follow the requirements and ensure successful implementation of signed contracts and technical agreements.
      * Focus on communication, actively communicate with users, take notes of user's questions and schedule, provide the necessary technical support.
      * Move quick and efficient, professional on delivery, installation, debugging, training and others.
       
      Warranty
      * We maintains 100% customer satisfaction, please give us feedback if you fell anything wrong with the product, we will make it right for you.
      * Our products are guaranteed with one year warranty and life-long tech support.
      * Provide solutions within 24 hours when there is problems feedback from customer.
       

      PACKING AND SHIPPING

      (1)We will ship products within 8-20 working days after the receipt of confirmation of your payment.

      (2)All products will be well packed by robust carton or wooden box so as to ensure goods can arrive safely.
      (3)Multiple shipping methods including express, sea freight, railway and so on for your choice, competitive shipping method will be advised to you.
      (4)If you go with your own forwarder, we will provide all necessary documents for customs clearance.
      (5)After shipping, we will remain attentive till goods well received.
       
      If you need detailed specification, please feel free to contact us.
      Digital AC20mA 40V Double Clamp Grounding Resistance Tester For On Site

      Test cases
      Digital AC20mA 40V Double Clamp Grounding Resistance Tester For On Site
      Digital AC20mA 40V Double Clamp Grounding Resistance Tester For On SiteDigital AC20mA 40V Double Clamp Grounding Resistance Tester For On Site

      Send your message to this supplier

      *From:
      *To:
      *Message:

      Enter between 20 to 4,000 characters.

      This is not what you are looking for? Post a Sourcing Request Now
      Contact Supplier
      Product Groups
      More