ZXKC-HB Circuit Breaker Dynamic Characteristics Tester Analyzer

Product Details
Customization: Available
Warranty: 1 Year
Time measuring range: 0.01ms-20000ms
Manufacturer/Factory & Trading Company
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
40
Year of Establishment
2012-02-28
Find Similar Products

Basic Info.

Model NO.
ZXKC-HB
Display
8.4" LED
Working environment
-10~+50 centigrade, relative humidity: ≤90%
Storage capacity
6000 groups on-site test results
DC Power supply
output 35~265V continuous, current output: ≤20A
AC Power supply
AC 220V ± 10%;50Hz ± 2%
Transport Package
Carton
Trademark
GDZX
Origin
China
HS Code
9026209000
Production Capacity
5000PCS/Month

Product Description

High voltage switch dynamic characteristics tester is specially developed and produced to test the dynamic characteristics of various high voltage switches, such as oil switches, vacuum switches and sulfur hexafluoride switches. It is equipped with 8.4 inch color display, windows system, friendly interface, touch panel, suitable for on-site work

Features:
1.    8.4"LED panel, windows operation system, humanized operation interface, visualized interface, touch screen, all these are handy for use.
2.      High-speed thermal printer is used for printing test data on site.
3.      Interior integrated operational power supply, without needing on-site secondary power supply, is convenient and easy to use on site. It provides the range adjustable power supply from DC20~265V with 20A of current. Randomly set the operation voltage values of breaking and closing coil, and conduct an low voltage operation test of breaker.
4.      Equip with liner sensors, rotation sensors, universal sensors and holders, and dedicated fixed multifunction connectors, which could be easy to mount.
5.      It is fit for all types about SF switch, GIS composite apparatus, vacuum switch, oil switch, produced in domestic or abroad. 
6.      Obtain overall data and graphs by one on-off action.
7.      Mainframe can store 6,000 groups of on-site test data (support external memory card), internal real time clock, easy to file.
8.      Equip with USB interface, which could save data directly in USB disk, and upload in computer to analyze and preserve.
9.      Simultaneously measure contacts in 12 channels, closing resistance in 6 channels.
10.    Generate standard envelop curves through the test data of switch testing from several instruments (2~10), then conduct analyses and comparisons, and switch vibration frequency analyses as well.
11.    Internal anti-jamming circuit could meet 500KV inner reliable use in transformer substation.

Technique Parameter:
1. Time measurement:
       12 channels  fixed opening (closing) time
       Opening (closing) inner-phase non-synchronism
       Opening (closing) phase-to-phase non-synchronism
       Opening (closing) bounces time (and times)
       Testing range: 0.01ms~20000ms. resolution:0.01ms
 2. velocity measurement :
       instant opening (instant closing) velocity
       Appointed time slot( stroke segment or angle segment) average velocity
3. velocity measurement range:
       1mm sensor 0.01~25.00m/s,
       0.1mm sensor 0.001~2.50m/s
       0.5 dgree angle sensor 1 cycle/ 0.5 degree
 4. stroke measurement:
       moving contact stroke (stroke)
       contact stroke (opening)
       overshoot stroke or retrace (over travel)
       three way liner sensor :50mm, resolution: 0.1mm
       360 wire sensor : 360 degree,resolution:0.5 degree
       Matching sensor: 300mm, 1000mm, acceleration sensor
5. Closing resister measurement:
       6 way  fixed separating (closing) time
       separating (closing) inner-phase asynchronism
       separating (closing) phase-to-phase non-synchronism
       closing (separating) bounce time (bounce times)
       closing resister time input
       Testing range: 0~1300Ω, resolution: 1Ω, error: 1%
6. current: maximum current output:20A
7. Instrument power supply : AC 220V ± 10%;50Hz ± 2%
8. DC power supply: voltage output: 35~265V continuous adjustment, current output: ≤ 20A(short time )
9. disconnecting switch measurement range
       (1). Voltage output: DC35~265V(adjustable)
       (2). Current output time: 0.01~20 s (settable)
       (3). Contact signal maximum acquisition time: 20s
       (4). Contact closing, opening time, three-phase asynchronism, bounce time and frequency measurable .
10. Dimension: 380x280x170mm
11. Operating environment: -10~+50 centigrade
12. relative humidity: ≤90%




 