Gold Member Since 2017
Audited Supplier
WUHAN GUODIAN ZHONGXING ELECTRICAL POWER EQUIPMENT CO., LTD.

Multi-Position Transformer Tester, Transformer Calibrating Device, Multi-Position Transformers Calibrating Device manufacturer / supplier in China, offering High Speed Multi-Position Intrument Transformers Calibrating Device tester, Electricity Meter Handheld Single Phase Three Phase Power Quality Analyzer, Three-phase Multifunction power check meter reference energy meter and so on.

(/ )

Supplier Homepage Product CT PT Tester High Speed Multi-Position Intrument Transformers Calibrating Device tester

High Speed Multi-Position Intrument Transformers Calibrating Device tester

FOB Price: US $22,000-35,000 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $22,000-35,000/ Piece
Get Latest Price
Port: Wuhan, China
Production Capacity: 500PCS/Month
Payment Terms: L/C, T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: ZXHQ-T
  • Trademark: GDZX
  • Origin: China
  • Warranty: 1 Year
  • Transport Package: Carton
  • HS Code: 9030841000
Product Description

Features: 

1. Full automatic testing bed is based on single chip to measure, control and display

2. With computer interface to achieve office automation, work efficiency much higher than before

3. Large LCD screen, user-friendly operation interface, massive measurement information

4. Auto measure the instrument transformer, auto switch the voltage current loading box

5. Good capture function, timely report to user about the errors

6. Accuracy: 2

7. The standard transformer is not necessary to be have the same turn ratio with the tested transformer, the test can carry out as long as the rated primary voltage or rated primary current of the standard transformer is larger than the rated value of the tested transformers.

Technical indicators:

1. Working condition

1) Temperature: 5ºC~40ºC

2) Relative humidity: <80%(25ºC)

3) Altitude: <2500m

4) Power supply frequency: 50Hz ±0.5Hz

5) Power supply voltage: 220V±5V

2. Measuring range

1) In-phase component (%): 0.0001~200.0 resolution: 0.0001

2) Quadrature component (min): 0.001~999.9 resolution 0.001

3) Impedance: (W): 0.0001~60.0 resolution:0.0001

4) Admittance(ms): 0.0001~60.0 resolution:0.0001

3. Basic error

1) In phase component: DX=±(X×2%+Y×2%±2d)

2) orthogonal component: DY=±(X×2%+Y×2%±5d)

"X""Y"--instrument display value

"5d"-- instrument quantization error 

3) Percentage: 1 class

4.Working scope:

1) Current (1%-149%)In(In=5A);(5%-149%)In(In=1A)
5. Working load

1) current: To relative to Tx < 0.12Ω cosΦ=1

6.Polarity error indication

1) There should be polarity indication when rated working current over 5%, error > 180%,

  Remark: if there is no polarity reminding when rated working current is over 10%, it is software failure, please don't increase current any more in order not to burn the instrument
7. Turn ratio error indication

1) There should be turn ratio error indication when rated working current over 5%, error >30%

8. Insulation and withstand test statement

1) Terminal Tx is linked with grounding terminal

2) Both K and D terminal are not linked with grounding terminal

3) Power supply socket can withstand 1.5KV to the case, time: 1min

 High Speed Multi-Position Intrument Transformers Calibrating Device tester
 

Send your message to this supplier
Avatar
Ms. Yan
Sales Manager
*From:
To: Ms. Yan
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now